Differences in Effectiveness Between Measuring Cuff ETT Using a Syringe and Cuff Inflator on Oxygen Saturation in Pneumonia Patients in the ICU

Kendon Suwahono, Achmad Dafir Firdausi, Rahmawati Maulidia

Abstract


Inaccuracy of ETT cuff pressure in intubated pneumonia patients will affect changes in oxygen saturation, so it is necessary to measure ETT cuff pressure using appropriate techniques. This study aims to analyze the difference in effectiveness between ETT cuff measurements using a syringe and an inflator cuff on oxygen saturation values in pneumonia patients. Comparative observational design with a cross sectional approach . There were 30 respondents using a total sampling technique, which were then distributed into 2 groups, namely the cuff inflator group and the syringe group with 15 patients each. Data were collected using observation sheets for ETT cuff measurements and oxygen saturation . The results of the Pearson statistical test analysis on ETT cuff measurements measured using a cuff inflator (p=0.01) and a syringe (p=0.004), both showed a p value <0.05, which means there is a significant correlation with the oxygen saturation value. The results of the difference test using the independent t test for the saturation value carried out by measuring the ETT cuff using a cuff inflator using a syringe showed that p=0.854 (>0.05 ) which means there is no difference. The conclusion of this research is that there is no difference between the saturation values of respondents who were measured using the ETT cuff using a cuff inflator and using a syringe. It is recommended that nurses increase their role in observing and maintaining ETT cuff pressure within the ideal range by using a cuff inflator or using a syringe at the service point.

Full Text:

PDF

References


Ajjapa, A.K. & Naz, S.S. (2017). Measurement of endotracheal tube cuff pressure in medchanically-ventilated patients on arrival to intensive care unit. Journal Evid. Based Med. Health. 4(34); 2032-2035

Alcan, A.O., et al. (2016). Effect of patient position on endotracheal cuff pressure in mechanically ventilated critically ill patirnts. Australian Critical Care.

Bulamba, Fred, et al. (2017). Achieving the recommended endotracheal tube cuff pressure. Hindawi Anesthesiology Research and Practice. Doi:2032748

Gilliland, L., Perrie, H., Scribante, J. (2015). Endotracheal tube cuff pressure alteration after changes in position in patients under mechanical ventilation. Joutnal Bras Pneumol. 34(5):294-297

Gilliland, L., Perrie, H., Scribante, J. (2015). Endotracheal tube cuff pressure in adult patients undergoing general anaesthesia in two Johannesburg academic hospitals. Southern African Journal of Anaesthesia and Analgesia. 21(3):81-84

Hikayati. (2017). Perbedaan SaO2 Pada Pengembangan Cuff ETT Menggunakan Spuit dan Cuff Inflator. Proceeding Seminar Nasional Keperawatan “Implikasi Perawatan Paliatif pada Bidang Kesehatan”, Vol. 3, No.1. E-ISSN 2685-4449

Hikayati. (2014). Pengaruh Pengembangan Cuff ETT Menggunakan Spuit dan Cuff-Inflator Terhadap Denyut Nadi dan Tekanan Darah Pasien Intubasi. Jurnal Keperawatan Soedirman (The Soudirman Journal of Nursing), vol.09, No.1.

Jaillette, E., et al. (2014). Optimal care and design of the tracheal cuff in the critically ill patient. Annals of Intensive Care, 4(7):2-7

Kementerian Kesehatan, RI. (2010). Keputusan Menteri Kesehatan Republik Indonesia Nomor 1778/MENKES/SK/XII/2010 Tentang Pedoman Penyelenggaraan Pelayanan ICU di Rumah Sakit. Jakarta

Kucan, M., Djekic, B., Ravljen, M. (2015). The Influence of endotracheal tube cuff on the occurrence of ventilator-assosiated pneumonia. Obzornik Zdravstvene Nege. 49(3);222-232

Lewis, S.L, et al. (2013). Medical Surgical Nursing; Assesment and Management of Clinical Problems. 9th Ed. Vol.2. Mosby Elsevier.

Lizy, C., et al. (2015). Cuff pressure of endotracheal tubes after changes in body position in critically ill patients treated with mechanical ventilation. Ametican Journal of Critical Care. 23 (1)

Pavlisa, G. Puretic, H., et al. (2016). The Impact of routine intensive care procedures on the endotracheal tube cuff pressure. European Respiratory Journal. 48;PA2147.

Setiyawan, S.Dwi Sulisetyawati. (2018). Studi Deskriptif : Tekanan Cuff Endotracheal Tube (ETT) Pada Pasien Terintubasi di Intensive Care Unit. Jurnal Terpadu Ilmu Kesehatan. Vol. 7, No.2, hlm 101-221

Setiyawan, S.Dwi Sulisetyawati. (2018). Hubungan Tekanan Cuff Endotracheal Tube (ETT) dengan Saturasi Oksigen pada Pasien terpasang Ventilasi Mekanik. Jurnal Keperawatan Sekolah Tinggi Ilmu Kesehatan Kendal. Vol. 10, No.3, hlm 196-200

Vincent, J.L. et al. (2017). Textbook of Critical Care. Sixth Edition.




DOI: http://dx.doi.org/10.36053/mesencephalon.v10i1.417

Refbacks

  • There are currently no refbacks.


Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.